This station provides hands-on training in aseptic technique and media fill testing, ensuring personnel understand the principles of working in laminar airflow primary engineering controls (PECs). Participants will perform aseptic transfers using sterile technique, simulate media fill testing, and discuss best practices for maintaining first air, minimizing contamination risks, and validating aseptic compounding competency. The session will also cover USP requirements for media fill testing, incubation, and evaluation of results.
Evaluate aseptic technique using key risk factors such as critical site protection, first air principles, and contamination prevention strategies.